Surgex SEQ-1210I Sequencer Conditioner

 

Program, sequence, protect, and condition your system’s power

SurgeX Sequencers provide the sequencing parameters, conditioning, shutdown thresholds, and surge protection needed to safeguard audio, video, broadcast, and computer equipment.

SurgeX Sequencers provide the sequencing parameters, conditioning, shutdown thresholds, and surge protection needed to safeguard audio, video, broadcast, and computer equipment. These units have extensive management features and are extremely easy to install, program, and use.

The SEQ models include two always-on receptacles and four programmable banks. They feature one “virtual” bank for controlling remote units, allowing for infinitely expanding distribution schemes. They are engineered with Advanced Series Mode surge elimination technology to provide top-of-the-line protection. Superior to conventional MOV circuitry or MOV-Hybrid designs, they completely eliminate surge energy up to 6,000 volts without producing harmful side effects such as earth contamination or common-mode disturbances.

 

FEATURES

  • Steel magnetic shielding rackmount case
  • Power sequencing
  • Pheonix connector for remote control capability
  • Protection Level: Advanced Series Mode
  • Power Configuration: 10A / 230V
  • Outlets: 10 IEC Outlets
  • Rack Size: 1 RU

SPECIFICATIONS

  • Load Rating: 10 Amps @ 230 Volts, 50Hz/60Hz (single phase)
  • Power Requirement (no load): 15 Watts
  • Number Of Sequenced Banks: 4 (2 receptacles each bank)
  • Number Of Always On Receptacles: 2
  • Surge Let-through Voltage (6000 Volt surge): 0 Volts
  • Safety Certification: IEC/EN 61643-1
  • Performance Rating: Grade A, Class 1, Mode 1
  • EMI/RFI Filter, Normal Mode (50 Ohm load):40 dB @ 100 KHz, 50dB @ 300 KHz, 50 dB @ 3 MHz, 50 dB @ 30 MHz
  • EMI/RFI Filter, Common Mode (50 Ohm load):18dB @ 300 KHz, 30 dB @ 1 MHz, 50 dB @ 5 MHz, 50 dB @ 20 MHz
  • Maximum Applied Surge Voltage: 6000 Volts *
  • Maximum Applied Surge Current: Unlimited (due to current limiting) *
  • Maximum Applied Surge Energy: Unlimited (due to current limiting) *
  • Endurance (C62.41-1991 category B3 pulses): 1 KV > 500,000; 3 KV > 10,000; 6 KV > 1000
  • Undervoltage Shutdown: 180 Volts (Auto resetting)
  • Overvoltage Shutdown: 280 Volts (Auto resetting)
  • Remote Turn-on Applied Voltage Range: 5 to 30 volts DC
  • Remote Turn-on Current Draw:Contact Closure: 1.0 mA
  • 5 V DC Applied Voltage: 0.1 mA
  • 12 V DC Applied Voltage: 0.5 mA
  • 24 V DC Applied Voltage: 2.0 mA
  • Auxiliary Relay Contact Rating: 30 Volts at 1 Amp
  • LED Output: 12 Volts DC, 10mA (Resistor included)
  • Delay Time Per Bank: 2, 5, 10, 15, 20 seconds (switchable)
  • Dimensions: 4.5cm H x 48.3cm W x 26.7cm D [Single Rack] 1.75” H x 19” W x 10.5” D
  • Weight: 5.9Kg (13 lbs)
  • Temperature Range: 5C to 35C
  • Humidity Range: 5% to 95% R.H. Non-condensing

 

 

 