Surgex ASM Surge Eliminator SXSX1210RTI

Request a Quote

SKU: SX-SX1210RTI Categories: ,
 

Description

Surgex ASM Surge Eliminator SXSX1210RTI

 

RACK MOUNT PREMIUM PROTECTION AND CONDITIONING FOR RACK EQUIPMENT

Featuring Advanced Series Mode surge elimination technology, the SurgeX Rack Mount product line safeguards sensitive equipment that relies on audio and video performance. Unlike common protection solutions, our patented protection technology is non-sacrificial and eliminates surge energy up to 6,000 volts without producing harmful side effects such as earth contamination or common-mode disturbances that can degrade the performance of AV systems. With SurgeX, your connected equipment will be protected from destructive spikes, surges, and inductive transients that can cause disruptions and catastrophic damage.

Remote Control Capability

Surge elimination and power conditioning with remote turn-on capability for audio, video, and security rack mount equipment

 

FEATURES

  • Steel magnetic shielding rackmount case
  • Phoenix connector remote control via rear panel (not sequenced)
  • 2.5m power cord
  • Thermal circuit breaker overload protection
  • Protection Level: Advanced Series Mode
  • Power Configuration: 10A / 230V
  • Outlets: 11 IEC Outlets
  • Rack Size: 1 RU
  • EMI/RFI filter
  • Inrush Current Elimination
  • Critical Over/Under Voltage Shutdown

SPECIFICATIONS

  • Load Rating: 10 Amps @ 230 Volts, 50Hz/60Hz (single phase)
  • Power Requirement (no load): 6 watts
  • Surge Let-Through Voltage (6000-volt surge): 0 volts
  • Safety Specification: IEC/EN 61643-1
  • Performance Rating: Grade A, Class 1, Mode 1
  • EMI/RFI Filter, Normal Mode (50-ohm load): 40dB @ 100 kHz; 50 dB @ 300 kHz; 50 dB @ 3 MHz; 50 dB @ 30 MHz
  • EMI/RFI Filter, Common Mode (50-ohm load): 18dB @ 300 kHz; 30 dB @ 1 MHz; 50 dB @ 5 MHz; 50 dB @ 20 MHz
  • Maximum Applied Surge Voltage: 6000 volts
  • Maximum Applied Surge Current: Unlimited, due to current limiting*
  • Maximum Applied Surge Energy: Unlimited, due to current limiting*
  • Endurance (C62.41-1991 Category B3 pulses): 1 kV>500,000; 3 kV>10,000; 6 kV>1000
  • Undervoltage Shutdown: 180 volts (auto resetting)
  • Overvoltage Shutdown: 280 volts (auto resetting)
  • Maximum Load Inrush Current During Power-up: 1000 Joules
  • Remote Turn-on Applied Voltage Range: 5 to 30 volts DC
  • Remote Turn-on Current Draw:Contact Closure: 1.5 mA
  • 5 V DC Applied Voltage: 0.1 mA
  • 12 V DC Applied Voltage: 1.5 mA
  • 24 V DC Applied Voltage: 5.0 mA
  • Auxiliary Relay Contact Rating: 30 Volts at 1 Amp
  • LED Output: 12 volts DC, maximum 20 mA (resistor required)
  • Littlite Connectors (QTY 2): N/A
  • Dimensions: 4.5cm H x 48.3cm W x 26.7cm D 1.75″ H x 19″ W x 10.5″ D
  • Weight: 5.0 kg (11 lbs)
  • Temperature Range: 5º to 35º C
  • Humidity Range: 5% to 95% R.H., non-condensing

 

 

 